Frog Leg Winding | Drum Winding | Gramme Ring Winding

Frog Leg Winding

Frog leg winding is a combination of a multiplex wave and a simplex lap winding in the same slots. It retains the advantages of both lap and wave windings without their inherit disadvantages.
Both lap and wave windings have equal number of parallel paths and they are conncted to the same commutator.The frog-leg winding have as many parallel paths as duplex lap winding because the simplex lap winding portion supplies P no. of parallel paths and the multiplex-wave section also provides Pno. of parallel paths, then total being 2P no. of paths in parallel.

Methods of Improving Commutation

To make the commutation satisfactory we have to make sure that the current flowing through the coil completely reversed during the commutation period attains its full value.

There are two main methods of improving commutation. These are
1) Resistance Commutation
2) E.m.f. Commutation

Commutation in DC Machine

The voltage generated in the armature, placed in a rotating magnetic field, of a dc generator is alternating in nature. The commutation in DC machine or more specifically commutation in DC generator is the process in which generated alternating current in the armature winding of a dc machine is converted into direct current after going through the commutator and the stationary brushes.

Applications of DC Generators

There are various types of dc generators available for several types of services. The applications of these dc generators based on their characteristic are discussed below:

DC Generators Performance Curves

Performance curves of a dc generator is that curves which shows the ability of delivering output voltage of a dc generator with the change in load current from no load to full load. These are also called characteristic curves. From the performance curve we can get a clear idea about the voltage regulation of various kind of dc generators. The lower the voltage regulation will be, the performance of the generator will be better.

Characteristic of DC Compound Wound Generators

In compound wound generators both the field windings are combined (series and shunt). This type of generators can be used as either long shunt or short shunt compound wound generators as shown in the diagram below. In both the cases the external characteristic of the generator will be nearly same.The compound wound generators may be cumulatively compounded or differentially compounded (discussed earlier in the type of generators).

Characteristics of Series Wound DC Generator

In these types of generators the field windings, armature windings and external load circuit all are connected in series as shown in figure below.
Series Wound DC Generator
Therefore, the same current flows through armature winding, field winding and the load.
Let, I = Ia = Isc = IL
Here, Ia = armature current
Isc = series field current
IL = load current
There are generally three most important characteristics of series wound dc generator which show the relation between various quantities such as series field current or excitation current, generated voltage, terminal voltage and load current.

Characteristic of Shunt Wound DC Generator

In shunt wound dc generators the field windings are connected in parallel with armature conductors as shown in figure below. In these type of generators the armature current Ia divides in two parts. One part is the shunt field current Ish flows through shunt field winding and the other part is the load current IL goes through the external load.

shunt wound dc generator
Three most important characteristic of shunt wound dc generators are discussed below:

Magnetization Curve of DC Generator

Magnetization curve of a dc generator is that curve which gives the relation between field current and the armature terminal voltage on open circuit.

Thursday, August 22, 2013

Self Excited Generator

When the field winding is supplied from the armature of the generator itself then it is said to be self excited generator. Now without generated e.m.f., field can not be excited in such generator and without excitation there can not be generated e.m.f. So one may obviously wonder, how this type of generator works. The answer to this is residual magnetism possessed by the field poles, under normal condition.
Practically through the generator is not working, without any current through field winding, the field poles possess some magnetic flux. This is called residual flux and the property is called residual magnetism. Thus when the generator is started, due to such residual flux, it develops a small e.m.f. which now drives a small current through the field winding. This tends to increase the flux produced. This in turn increases the induced e.m.f. This further increases the field current and the flux. The process is cumulative and continues till the generator develops rated voltage across its armature. This is voltage building process in self excited generators.
Based on how field winding is connected to the armature to drive its excitation, this type is further divided into following three types.
i) Shunt generator
ii) Series generator
iii) Compound generator
Shunt Generator
When the field winding is connected in parallel with the armature and the combination across the load then the generator is called shunt generator.
The field winding has large number of turns of thin wire so it has high resistance. Let Rsh be the resistance of the field winding.
Fig. 1 Shunt generator


1.1 Voltage and Current Relations
From the Fig. 1, we can write
Ia = IL + Ish
Now voltage across load is Vt which is same across field winding as both are in parallel with each other.
... Ish = Vt /Rsh
While induced e.m.f. E, still requires to supply voltage drop Ia Ra and brush contact drop.
... E = Vt + Ia Ra + Vbrush
Where E = (ΦPNZ)/(60A)
In practical, brush contact drop can be neglected.
Series Generators
When the field winding is connected in series with the armature winding while supplying the load then the generator is called series generator. It is shown in the Fig. 1.
Field winding, in this case is denoted as S1 and S2. The resistance of series field winding is very small and hence naturally it has less number of turns of thick cross-section wire as shown in the Fig. 1.
Fig. 1 Series generators


Let Rse be the resistance of the series field winding.
1.1 Voltage and current Relations
As all armature, field and load are in series they carry the same current.
... Ia = Ise = IL
Where Ise = Current through series field winding.
Now in addition to drop Ia Ra, induced e.m.f. has to supply voltage drop across series field winding too. This is Ise Rse i.e. Ia Rse as Ia = Ise. So voltage equations can be written as,
E = Vt + Ia Ra + Ia Rse + Vbrush
... E = Vt + Ia (Ra + Rse) + Vbrush
where E = (ΦPNZ)/(60A)
Compound Generator
In this type, the part of the field winding is connected in parallel with armature and part in series with the armature. Both series and shunt field windings are mounted on the same poles. Depending upon the connection of shunt and series field winding, compound generator is further classified as : i) Long shunt compound generator, ii) Short shunt compound generator.
1.1 Long Shunt Compound Generator
In this type, shunt field winding is connected across the series combination of armature and series field winding as shown in the Fig. 1.
Fig. 1 Long shunt compound generator


Voltage and current relations are as follows.
From the Fig. 1.
Ia = Ise
and Ia = Ish + IL
Voltage across shunt field winding is Vt.
Ish = Vt /Rsh
where Rsh = Resistance of shunt field winding
And voltage equation is,
E = Vt + Ia Ra + Ia Rse + Vbrush
Where Rse = Resistance of series field winding
1.2 Short Shunt Compound Generator
In this type, shunt field winding is connected, only across the armature, excluding series field winding as shown in the Fig. 2.
Fig. 2 Short shunt compound generator

Voltage and current relations are as follows.
For the Fig. 2, Ia = Ise + Ish
and Ise = IL
... Ia = IL + Ish
The drop across shunt field winding is drop across the armature only and not the total Vt, in this case. So drop across shunt field winding is E -Ia Ra .
Ish = (E - Ia Ra ) / ( Rsh)
Now the voltage equation is E = Vt + Ia Ra + Ise Rse + Vbrush
... Ise = IL
... E = Vt + Ia Ra + IL Rse + Vbrush
Neglecting Vbrush , we can write,
E = Vt + Ia Ra + IL Rse
E - Ia Ra = Vt + IL Rse
Ish = (Vt + IL Rse) / ( Rsh)
Any of the two above expression of Ish can be used, depending on the quantities known while solving the problems.
1.3 Cumulative and Differential Compound Generator
It is mentioned earlier that the two windings, shunt and series field are wound on the same pole. Depending on the direction of winding on the pole, two fluxes produced by shunt and series field may help or may oppose each other. This facts decides whether generator is cumulative or differential compound. If the two fluxes help each other as shown in Fig. 3 the generator is called cumulative compound generator.
Fig. 3 Cumulative compound generator

ΦT = Φsh + Φse
Where Φsh = Flux producd by shunt
Φse = Flux produced by series, field winding
If the two windings are wound in such a direction that the fluxes produced by them oppose each other then the generator is called differential compound generator. This is shown in the Fig. 4.
ΦT = Φsh - Φse
Where Φsh = Flux produced by shunt field winding.
Φse = Flux produced by series field winding.
Fig. 4 Differential compound generator

Separately Excited Generator

When the field winding is supplied from external, separate d.c. supply i.e. excitation of field winding is separate then the generator is called separately excited generator. Schematic representation of this type is shown in the Fig.1.
Fig. 1 Separately excited generator


The field winding of this type of generator has large number of turns of thin wire. So length of such winding is more with less cross-sectional area. So resistance of this field winding is high in order to limit the field current.
1.1 Voltage and Current Relations
The field winding is excited separately, so the field current depends on supply voltage and resistance of the field winding.
For armature side, we can see that it is supplying a load, demanding a load current of IL at a voltage of Vt which is called terminal voltage.
Now Ia = IL
The internally induced e.m.f. E is supplying the voltage of the load hence terminal voltage Vt is a part of E. But E is not equal to Vt while supplying a load. This is because when armature current Ia flows through armature winding, due to armature winding resistance Ra ohms, there is a voltage drop across armature winding equal to Ia Ra volts. The induced e.m.f. has to supply this drop, along with the terminal voltage Vt. To keep Ia Ra drop to minimum, the resistance Ra is designed to be very very small. In addition to this drop, there is some voltage drop at the contacts of the brush called brush contact drop. But this drop is negligible and hence generally neglected. So in all, induced e.m.f. E has three components namely,
i) Terminal voltage Vt
ii) Armature resistance drop Ia Ra
iii) Brush contact drop Vbrush
So voltage equation for separately excited generator can be written as,
E = Vt + Ia Ra + Vbrush
Where E = (ΦPNZ)/(60A)
Generally Vbrush is neglected as is negligible compared to other voltages.